Help your buddy out Mark- don't let the rest of the world know what many of us already do. Just some friendly advice- Peace piss? Leave it to our resident programming expert Mark, the Super-Downloader My post included a note to that effect.
However, your reply was better. Thanks for the correction. Thanks for all your responses. I now realize what I did wrong. I made the master code the same as the "go to program" code but didn't have the latter enabled as a master code does that make sense? Evidently, the panel defalts to the settings for the "go to program" code. Enabling it as a master in location 43 I think did the trick.
Thanks again, Mike Tolliver. From your ankles? Not even close to the ankles "Tex. I am failing now to program the panel Bob La Londe. I hated the old Ranger panels. I have the same problem trying to get NX-8V2 program code back to default. I purchased a home which has a NX-8V2 security system installed. The installer is no longer in business and the Program Code has been changed from the default. However when I try to connect to the alarm panel I get the error: "Error Reading data from Module number I'm not at all familiar with alarm systems.
Can anyone give me any ideas? If you can get a direct connect adapter, you can access the panel and change whatever you want, even if they changed all the lockout parameters. But, it would be easier for a homeowner to just buy a board as others have said, and just program it the way you want. Jim Davis. For alarm installers: The direct connect module just hooks up to the board keypad wiring and can connect to the laptop thru a usb port. It has the ability to store 4 separate panel configurations to quickly upload to a panel onsite, if you require that.
It is best used for direct access to a locked board. With it, you do not need to know what any master, installer, or download access code is. The NX-8E is probably the most flexible, durable, and. Took a look this morning as I could not get it to communicate and checked what I had my panel set at and it was indeed 4.
Each segment has up to 8 data positions 1 2 3 4 5 6 7 8 which are either turned on you see the number displayed on the screen or OFF the individual number is NOT displayed. Did you miss your activation email? Some locations have only one segment and others have several. There was no corresponding value in Vera for that baud rate so I left it at The settings below show how to cadex the NX8-e directly from the alarm lcd panel: Somehow my baud rate was set to for my serial connection on Vera and when I went back through all my settings I noticed that this post indicated my baud rate should be set to option 4 31, Check out our YouTube training programmign.
This website uses cookies to improve your experience while you navigate through the website. The smallest is the NX-4, with 8 on-board zones. The largest panel is the Caddx NX-8, with 8-zones on-board, expandable to This range of zones will cover anything from an apartment or condo to a large house.
The only supplier I saw still listing Caddx equipment has many fewer items, compared to years past. All three General Electric products Networx systems can handle a combination of hardwired and wireless zones, so they can easily be installed in new or existing construction.
This installation flexibility, along with low cost, make a Caddx alarm panel a good choice for a DIY security system. Caddx wireless transmitters are the standard NX-series sensors used by many other GE systems.
Wireless sensors are available for doors and windows, motions, glassbreaks, smoke detectors, etc. Wireless keypads and keyfobs can also be added to allow easy arming, disarming, and other functions. Need more than 48 zones?
GE Simon 3 Alarm System. The Caddx NX-4 is often sold as a package, with everything needed to build a complete basic system. Its small size makes it a good fit for an apartment, condo, or townhouse-size home.